Documents / Report

The Roswell Report: Fact vs. Fiction in the New Mexico Desert

USAF / The Black Vault · 1995 · 882 pages · text by OCR

The Roswell Report: Fact versus Fiction in the New Mexico Desert was published by Headquarters United States Air Force in 1995. The Black Vault distributes this copy. It reproduces the report by Col. Richard L. Weaver and the synopsis by 1st Lt. James McAndrew, both written after a General Accounting Office inquiry requested by Representative Steven Schiff. The Air Force search found no evidence of an extraterrestrial craft or crew. It concluded that the Roswell debris most likely came from NYU Flight No. 4, a Project MOGUL balloon train.

  • p. 193 …overhead and followed the balloons out to sea. I have no idea about the results that…
  • p. 200 …the regular 334 that we had at sea level. From that they could deduce the temperature…
  • p. 243 …actually located on the jurisdictional lines between Sea Girt and Springlake, New Jersey. It was an…
  • p. 244 …The Sea Girt Inn? A: Exactly. That's where John had his office, and I was…
  • p. 320 …alone is about 24,000 miles at sea level, and about 4500 miles at 45,000…
  • p. 325 …twenty-five (25) feet at their largest sea-level diameter. The sonic unit was a combination…
  • p. 378 …per hour when one-fifth inflated at sea level). One other type of balloon which has…
  • p. 402 …Let us, then, compare the rate of leakage at any given altitude with leakage at sea…
  • p. 404 …The leakage at any altitude may be expressed as a function of leakage at sea level…
  • p. 405 Comparing rate of leakage at 40,000 feet with leakage at sea level: $$ \frac {L _ {4…
  • p. 407 …If a 20-foot diameter balloon $ \frac{1}{1 0} $ full were tested at sea level…
  • p. 408 …At sea level this is equivalent to 5.32 gm/hr. for a 20-foot diameter…
  • p. 414 …Using the rules of subsonic aerodynamics, Picard suggests that air at sea level escaping at 1333…
  • p. 415 …air at sea level (lb./ft. $ ^{3} $ ) 14.7 = pressure of air at sea level (psi…
  • p. 432 …to about 20 millibars and increased to sea-level pressure at different temperatures. The most comprehensive…
  • p. 563 …The height above mean sea level as determined from pressure measurements used in this work with…
  • p. 644 …point at which the radiosonde reaches the sea surface. ## 2. Earlier attempts There have been numerous…
  • p. 645 …The balloons floated between the surface and 30,000 ft above sea level; those which reached…
  • p. 704 …Met Gifford who has 90' sea rescue boat this project is planning to use. Stayed at…
  • p. 719 …Worzel working on gravity at sea. Saw Geo Woollard and the Ryders. Woollard after Guggenheim fellowship…
  • p. 779 …the launching site is markedly different from sea level, a shift in this curve is needed…
  • p. 817 …balloon at all times with respect to sea level. On this curve also it is customary…
  • p. 825 …The height above mean sea level as determined from pressure measurements used in this work with…
From this survey and a study of aerostatics, 10, 16, 16 it appeared that a non-extensible balloon is highly desirable due to the vertical stability exhibited when such a balloon is full of the lifting gas: A non-extensible balloon with no diffusion or leakage through the walls, which could withstand a high internal pressure, would automatically remain at the density where the buoyancy of the full balloon equaled the load. In practice, control devices are needed to offset the leakage and diffusion of the lifting gas and to correct for the motion of the balloon due to diurnal changes of the balloon's temperature and to correct for vertical wind currents in the atmosphere. It was decided to use a plastic as the balloon fabric, since available plastics have suitable characteristics, and are also relatively inexpensive as compared to coated fabrics.

The desirable properties to be considered in the selection of a plastic balloon material are:

a. Ease of fabrication

b. High tear resistance

c. Light weight

d. High tensile strength

e. Chemical stability

f. Low permeability

g. Low brittle temperature

h. High transparency to heat radiation

Table I is a qualitative-characteristics catalog of the film and fabrics investigated. The data in the table are presented as approximations because of the great variations of a given property with choice of samples and test methods. From this study, polyethylene, nylon, saran, and neoprene-