Documents / Report

The Roswell Report: Fact vs. Fiction in the New Mexico Desert

USAF / The Black Vault · 1995 · 882 pages · text by OCR

The Roswell Report: Fact versus Fiction in the New Mexico Desert was published by Headquarters United States Air Force in 1995. The Black Vault distributes this copy. It reproduces the report by Col. Richard L. Weaver and the synopsis by 1st Lt. James McAndrew, both written after a General Accounting Office inquiry requested by Representative Steven Schiff. The Air Force search found no evidence of an extraterrestrial craft or crew. It concluded that the Roswell debris most likely came from NYU Flight No. 4, a Project MOGUL balloon train.

  • p. 193 …overhead and followed the balloons out to sea. I have no idea about the results that…
  • p. 200 …the regular 334 that we had at sea level. From that they could deduce the temperature…
  • p. 243 …actually located on the jurisdictional lines between Sea Girt and Springlake, New Jersey. It was an…
  • p. 244 …The Sea Girt Inn? A: Exactly. That's where John had his office, and I was…
  • p. 320 …alone is about 24,000 miles at sea level, and about 4500 miles at 45,000…
  • p. 325 …twenty-five (25) feet at their largest sea-level diameter. The sonic unit was a combination…
  • p. 378 …per hour when one-fifth inflated at sea level). One other type of balloon which has…
  • p. 402 …Let us, then, compare the rate of leakage at any given altitude with leakage at sea…
  • p. 404 …The leakage at any altitude may be expressed as a function of leakage at sea level…
  • p. 405 Comparing rate of leakage at 40,000 feet with leakage at sea level: $$ \frac {L _ {4…
  • p. 407 …If a 20-foot diameter balloon $ \frac{1}{1 0} $ full were tested at sea level…
  • p. 408 …At sea level this is equivalent to 5.32 gm/hr. for a 20-foot diameter…
  • p. 414 …Using the rules of subsonic aerodynamics, Picard suggests that air at sea level escaping at 1333…
  • p. 415 …air at sea level (lb./ft. $ ^{3} $ ) 14.7 = pressure of air at sea level (psi…
  • p. 432 …to about 20 millibars and increased to sea-level pressure at different temperatures. The most comprehensive…
  • p. 563 …The height above mean sea level as determined from pressure measurements used in this work with…
  • p. 644 …point at which the radiosonde reaches the sea surface. ## 2. Earlier attempts There have been numerous…
  • p. 645 …The balloons floated between the surface and 30,000 ft above sea level; those which reached…
  • p. 704 …Met Gifford who has 90' sea rescue boat this project is planning to use. Stayed at…
  • p. 719 …Worzel working on gravity at sea. Saw Geo Woollard and the Ryders. Woollard after Guggenheim fellowship…
  • p. 779 …the launching site is markedly different from sea level, a shift in this curve is needed…
  • p. 817 …balloon at all times with respect to sea level. On this curve also it is customary…
  • p. 825 …The height above mean sea level as determined from pressure measurements used in this work with…
## Flight 92: Released from Alamogordo, New Mexico, 0911 MST, August 31, 1948 Recovered at Ft. Stockton, Texas

On this flight an automatic ballast valve (with ballast meter) was used to support a 20-foot, .001" polyethylene balloon. The automatic ballast valve operated properly for about six hours, and 3000 grams of ballast was exhausted soon after sunset. In this case (Figure 41) the floating level of the

Figure 41

balloon was not seriously affected by sunset as was the case in Flight 90, since the balloon had already descended to the activation level of the automatic ballast valve. This descent followed about three hours of relatively stable flight during which time no ballast was released. The 5000-foot descent represents the delay in operation caused by the activation of the aneroid capsule by a minimum-pressure switch, added to the lag of the aneroid itself. Following the initial activation at about 38,500 feet, small oscillations were introduced into the flight pattern by the action of the automatic ballast valve.

Flight 92 provides a good example of the control of a balloon's altitude by the use of a pressure-set automatic ballast valve. In such a flight there is no tendency to rise to higher and higher levels. The adulteration of the lifting gas with air reduces the buoyancy of the balloon, and through the ballast-valve control, the load is diminished to the same extent so that equilibrium is maintained at the activation pressure of the automatic ballast valve's aneroid. In this flight the altitude constancy achieved was the best of all flights made to date. For seven hours and 35 minutes this balloon was held within 1000 feet at 38,000 feet MSL. (At this altitude 1000 feet corresponds to a pressure difference of 10 millibars.)

Cited by

Cases discussed

About this file

Report, cited by the archive. The PDF is mirrored here; the original link is under it. The text was read from the page images by an OCR model; expect the odd misread word. 882 pages are in the text index: search them above, or from the library's search.