Documents / Report

The Roswell Report: Fact vs. Fiction in the New Mexico Desert

USAF / The Black Vault · 1995 · 882 pages · text by OCR

The Roswell Report: Fact versus Fiction in the New Mexico Desert was published by Headquarters United States Air Force in 1995. The Black Vault distributes this copy. It reproduces the report by Col. Richard L. Weaver and the synopsis by 1st Lt. James McAndrew, both written after a General Accounting Office inquiry requested by Representative Steven Schiff. The Air Force search found no evidence of an extraterrestrial craft or crew. It concluded that the Roswell debris most likely came from NYU Flight No. 4, a Project MOGUL balloon train.

  • p. 8 …Computer Specialist, Office of the Secretary of the Air Force, Pentagon; George Cully, Historian, 81st Training…
  • p. 20 …FOR THE SECRETARY OF THE AIR FORCE FROM: SAF/AAZ 1720 Air Force Pentagon Washington, DC…
  • p. 56 …SAF/FMPF, Room 4C228, Pentagon SUBJECT: Central Point of Contact, GAO Code 701034 2. You will…
  • p. 58 # DEPARTMENT OF THE AIR FORCE WASHINGTON DC 20330-1000 OFFICE OF THE SECRETARY MEMORANDUM FOR DISTRIBUTION…
  • p. 59 …SAF/AAZ 1720 Air Force Pentagon Washington DC 20330-1720 SUBJECT: GAO Review on Records Management…
  • p. 75 …HQ USAF/XOWP 1490 Air Force Pentagon Washington DC 20330-1490 SUBJECT: GAO Review on Records…
  • p. 77 10 March 1994 SAF/AAIQ 1610 Air Force Pentagon Washington, DC 20330-1610 MEMORANDUM FOR SAF…
  • p. 78 …They noted that the histories for the 509th Bomb Group and Wing for Roswell Army Air…
  • p. 145 …the Pentagon if he had a problem with that he could take it up with the…
  • p. 185 …Perhaps you have it from the Pentagon files already, from the AG files. ## Q: We have…
  • p. 246 …Following that, I spent more than three years on the Air Staff in the Pentagon. Q…
  • p. 268 …Force Pentagon Washington, DC 20330-1720 SUBJECT: Report of Findings on Balloon Research The following report…
9 = the acceleration of gravity (ft./sec. $ ^{2} $ )

$ A_{0} $ area of the opening (ft.2)

h = head of fluid causing flow (ft.)

since $ h=\frac{1 4 4 \Delta p}{d_{q}} $ , we have:

$$
\Delta p = \frac {d g}{2 8 8 g} \left(\frac {1}{C _ {d} A _ {a}} \cdot \frac {d V}{d t}\right) ^ {2} \quad p s i
$$

where $ d_{g} $ is density of the lifting gas (1b./ft. $ ^{3} $ ).

From equation (7) we have:

$$
\frac {d V}{d t} = \frac {d z}{d t} \frac {V}{2 7 8 0 0} f t ^ {3} / \sec
$$

therefore:

$$
\Delta p = \frac {d g}{2 8 8 g} \left(\frac {1}{C _ {d} A _ {a}} \frac {d z}{d t} \cdot \frac {V}{2 7 8 0 0}\right) ^ {2}
$$

psi

Comparing equations (10) and (13) we see that if the equations are equal:

$$
\frac {1}{2 8 8 g C _ {d} ^ {2}} = \frac {1 4 . 7}{1 3 3 3 ^ {2} d _ {a 0}}
$$

If we let $ C_{d}=.975 $ , a reasonable value for the relatively low velocity flow of gas through the appendix, we have:

$$
\frac {1}{2 8 8 g C _ {d} ^ {2}} = 1 1 3. 5 \times 1 0 ^ {- 6} f t - \sec^ {2} / \ln^ {2}
$$

$$
\frac {1 4 . 7}{1 3 3 3 ^ {2} d _ {a 0}} = 1 1 4. 8 \times 1 0 ^ {- 6} f t - \sec^ {2} / \mathrm {i n} ^ {2}
$$

Therefore, the equations (10) and (13) are equal and interchangeable.

It may be noted from equations (10) and (13) that for any given balloon, appendix area and balloon volume are fixed, and the related variables are lifting gas density, rate of rise, and allowable back pressure. For any given allowable back pressure greater rates of rise are allowable at higher altitudes (where $ \mathbf{d}_{g} $ is lower).

Once a floating altitude has been decided upon or it has been decided to carry a given load as part of the balloon system, we can find a maximum allowable rate of rise. We must consider

Cited by

Cases discussed

About this file

Report, cited by the archive. The PDF is mirrored here; the original link is under it. The text was read from the page images by an OCR model; expect the odd misread word. 882 pages are in the text index: search them above, or from the library's search.