Documents / Report

The Roswell Report: Fact vs. Fiction in the New Mexico Desert

USAF / The Black Vault · 1995 · 882 pages · text by OCR

The Roswell Report: Fact versus Fiction in the New Mexico Desert was published by Headquarters United States Air Force in 1995. The Black Vault distributes this copy. It reproduces the report by Col. Richard L. Weaver and the synopsis by 1st Lt. James McAndrew, both written after a General Accounting Office inquiry requested by Representative Steven Schiff. The Air Force search found no evidence of an extraterrestrial craft or crew. It concluded that the Roswell debris most likely came from NYU Flight No. 4, a Project MOGUL balloon train.

  • p. 8 …Computer Specialist, Office of the Secretary of the Air Force, Pentagon; George Cully, Historian, 81st Training…
  • p. 20 …FOR THE SECRETARY OF THE AIR FORCE FROM: SAF/AAZ 1720 Air Force Pentagon Washington, DC…
  • p. 56 …SAF/FMPF, Room 4C228, Pentagon SUBJECT: Central Point of Contact, GAO Code 701034 2. You will…
  • p. 58 # DEPARTMENT OF THE AIR FORCE WASHINGTON DC 20330-1000 OFFICE OF THE SECRETARY MEMORANDUM FOR DISTRIBUTION…
  • p. 59 …SAF/AAZ 1720 Air Force Pentagon Washington DC 20330-1720 SUBJECT: GAO Review on Records Management…
  • p. 75 …HQ USAF/XOWP 1490 Air Force Pentagon Washington DC 20330-1490 SUBJECT: GAO Review on Records…
  • p. 77 10 March 1994 SAF/AAIQ 1610 Air Force Pentagon Washington, DC 20330-1610 MEMORANDUM FOR SAF…
  • p. 78 …They noted that the histories for the 509th Bomb Group and Wing for Roswell Army Air…
  • p. 145 …the Pentagon if he had a problem with that he could take it up with the…
  • p. 185 …Perhaps you have it from the Pentagon files already, from the AG files. ## Q: We have…
  • p. 246 …Following that, I spent more than three years on the Air Staff in the Pentagon. Q…
  • p. 268 …Force Pentagon Washington, DC 20330-1720 SUBJECT: Report of Findings on Balloon Research The following report…
A review of this system by members of the University staff has been published in "Transactions of the American Geophysical Union(2)". Earlier work on this development has been reported by members of this Research Division in"Technical Report 93.01(3) and in the "Journal of the American Meteorological Society"(4).

A manual for those interested in making use of balloon systems of this type has also been published as "Section II, Operations" of our Technical Report 93.02"(1). This report consists of a discussion of instrumentation for balloon systems, techniques for launching and trading, and telemetering from balloons as developed and tested at New York University.

## C. Telemetering From Balloon Systems

The second requirement of this project was the investigation, development, and testing of balloon borne telemetering systems. The development was completed in June of 1948 and a final report(7) of work accomplished and recommendations made to the sponsor at that time.

Two types of transmitter units were suggested as a means of accomplishing the telemetering of data from a balloon to ground station receivers. A high frequency system, making use of line-of-sight transmission allows for accurate positioning of the balloon system from two ground stations. The line-of-sight characteristic, however, limits the range of this type transmitter, and ranges in excess of 250 miles are not to be expected with a balloon system floating at 40,000 ft.

Three line of sight transmitters were designed for use in balloon work. The first, the FM-1, was designed to operate at 72 mc, using a conventional reactance tube modulator. Several stages were included to deliver 1 watt output at the design frequency. The unit was quite complicated and the required input power large due to the requirement for several stages to transmit at the high frequency. Fig. 4 is a schematic of the FM-1 transmitter.

In order to overcome this limitation of FM sets, a two tube transmitter was developed (Fig. 5). Variation in vacuum tube resistance is used to modulate the oscillator plate voltage of a self-excited oscillator in accordance with the audio signal. This provides the frequency modulation desired. In order to maintain a stable center frequency and render the oscillator insensitive to changes in supply voltage, a neon tube voltage regulator was included.

Cited by

Cases discussed

About this file

Report, cited by the archive. The PDF is mirrored here; the original link is under it. The text was read from the page images by an OCR model; expect the odd misread word. 882 pages are in the text index: search them above, or from the library's search.