This Defense Intelligence Reference Document, dated 31 March 2010 and numbered DIA-08-1003-020, was prepared by the Defense Intelligence Agency's Defense Warning Office under its Advanced Aerospace Weapon System Applications Program. It surveys biosensors and biomedical microelectromechanical systems, covering brain-implanted micromachine neuroelectrodes, drug-delivery pumps, glucose sensors, neural interfaces, retinal prostheses, microfluidic lab chips, NASA cell-culture systems and microcantilever sensors. It concludes that the field is expanding rapidly, with nanomechanical systems expected to follow.
From the source:Release of 2026-09-18 Incident: 3/31/10, Las Vegas, Nevada. Released with redactions. This document is a Defense Intelligence Reference Document (DIRD), a technical reference format used by the Defense Intelligence Agency (DIA) to capture baseline knowledge on a specific topic for later analytic use. DIRDs are best understood as reference and synthesis products rather than as original research. It is one of 38 DIRDs produced under the Advanced Aerospace Weapon System Applications Program (AAWSAP) between 2009 and 2011. Because AAWSAP’s scope permitted a broad range of supporting topics, not every DIRD in the series directly concerns aerospace systems or future threat assessment. The following summary reflects the DIRD’s scope and framing at the time of writing and should not be read as implying current validation of the concepts discussed. This DIRD surveys biosensors and BioMEMS, a broad class of miniature biomedical devices that combine microscale engineering with sensing, fluid handling, stimulation, or drug-delivery functions. The report reviews major application areas including implantable blood-chemistry sensors, neural interfaces, neurostimulation, drug-delivery pumps, microfluidic systems, and emerging nanoscale extensions of the field, while emphasizing that miniaturization can improve sensitivity and enable functions that are difficult or impossible at larger scales. However, it also makes clear that practical development is constrained by biocompatibility, long-term stability, sensor drift, device degradation inside the body, and the high regulatory burden associated with implantable medical systems. The document presents BioMEMS as a rapidly growing and productive field whose future advances are likely to come through continued improvements in fabrication, materials, and reliability.
UNCLASSIFIED/ /P'OR: OP'P'l@IAL WS& 0Nk¥
Figure 13. A MEMS Thermopile Glucose Sensor (Towe et al., Arizona State University)
Heat energy released in the gel is measured by the thermopile and is characterized in
terms of kiloJoules (kJ) per mole of glucose consumed. At concentrations of glucose
that are common in the blood stream, the temperature rise is very small, on t he order
of a hundredth of a degree (10 millidegrees) .
Measuring this temperature change in the presence of ambient body heat or room
temperature changes of a few degrees is a daunting task, but can be done.
The measurement of the small reaction temperature in the face of possible ambient
temperature shifts is accomplished by the use of a differential temperature
measurement system.
This sensor employs what is known as the Seebeck Effect whereby dissimilar metals
heated at their junction produce a voltage that is proportional to temperature. This
concept is shown in Figure 14. This principle is then implemented as an array of metal
junctions that when connected in series produce a higher output in order to detect
smaller temperature changes.