Documents / FOIA release
The Roswell Report: Fact versus Fiction in the New Mexico Desert was published in 1995 by Headquarters United States Air Force. It was written in response to Representative Steven H. Schiff's request and a General Accounting Office audit, and it contains Col. Richard L. Weaver's report and 1st Lt. James McAndrew's synopsis, along with attachments, appendices and photographs. The report says researchers found no evidence of an extraterrestrial craft or crew. It concludes that the 1947 debris came from a Project MOGUL balloon train.
“Lund”1 page
t.mperature recording is confined to the lo'tier 2 inches of the drum so as to interfere as little as poasible with the pressure record when the bel loon float• above 30,000 teet. Recording is accomplished by three pens which scratch carbon from a smoked aluminum toil. This method eliminates the need :for liquid ink and applies a minimwn of pressure to the recording drum. The recording dr~ rotates once in twelve hours. Therefore, it a :flight lasts over twelve hours, the trace will overlap. Such a record is shown in Figure 36. The clock runs for 36 to 40 hours on one winding. Preparation of the barograph :for use on a balloon a~ension requires the followinga (a) Place an aluminum :foil about 10 inches long by 3 3/4", .002" thick on the drum. Care should be taken to have the overlapping edge of the :foil :face in the direction of rotation of the drum so the. t the stylus &lides ott the edge in- stead ot catching and tearing the :foil. A few drops of rubber cement along each edge or the :foil are sufficient to :fasten the roil to the drum and will not interfere with removal of the foil after reoovery or the barograph. (b) Wind the clock. The clock should not be wound tightly since at the low temperatures encountered in the upper atmosphere the clock spring may snap. However, if the clock is wound an hour or so before release, it·will be sufficiently relaxed by the time the low temperatures are reached. (c) Check pressure of the marking pens. Too much pressure of the pens on the drum will introduce an error due to the frictional lag. When the drum is removed :from the clock mechanism, and the pen lifter released, the stylus points should touch the clock housing lightly. (d) Smoke the drum. A very thin, tine-grained carbon film should be deposited on the aluminum foil. The best result will be obtained by use of a bright yellow gas flame, although a kerosene flame gives a satisfactory coating. Solid or liquid -66-
FOIA release, from the osd collection. The PDF is mirrored here; the original link is above. 993 pages are in the text index: search them above, or from the library's search.