Documents / FOIA release

roswell

Office of the Secretary of Defense · 993 pages · text from the file's own layer

The Roswell Report: Fact versus Fiction in the New Mexico Desert was published in 1995 by Headquarters United States Air Force. It was written in response to Representative Steven H. Schiff's request and a General Accounting Office audit, and it contains Col. Richard L. Weaver's report and 1st Lt. James McAndrew's synopsis, along with attachments, appendices and photographs. The report says researchers found no evidence of an extraterrestrial craft or crew. It concludes that the 1947 debris came from a Project MOGUL balloon train.

  • p. 547 Flight 17a Released from Alamogordo, New :Mexioo, 1647 liST, September 9, 1947 Recovered at Croft, Kansas…
  • p. 743 …The balloon was ultimately recovered from Croft, Kansas, a distance of 530 miles from the release…
properly at 12,000 teet, but the air entrapped _in its aneroid wae heated
and cau..d the operating le~el to be at the lower ftlue. 1'hiw would
correspond to a superheat ct aooc above the air temperature.
Later flights showed that. the type ot load a1;1aohm8nt ueed an thie
balloan was unsatiltactoeyJ honnr, with proper rigging, cells ot .008"
t.hickneu were good nhicles ae they usually showed ftl"J low dittulion and
gae leakage.
Near the end of iohe recorded data, the height-tiM cu"e shows large
oscillations about a pressure plane (Figure 6). '.ftlree tactore which probabl7
II HEIGHT-TIME CURVE
FLIGHT 10
Released at~
.1\jy 5, 1947-0SOIMS:r
Figure 6
contributed to this instability were: (1) the turbulent motion of' the heated
air over the desert, (2) the change• in temperature ot air in the aneroid
val~e as intermittent clouds shut off' the sun, and (3) the overcompensation
caused by the valve-controlled ballast flow.
On this flight the .first "destruction device" was used for the purpose
of' brlbgi.ng down the balloon after a f'ixed time to prevent excessive inter-
ference in air-traffic lanes. This particular model was a clock-dri~en
device which failed to operate, probably because of' low temperatures causing
unequal contraction within the movement. Its action was to consist o.f de-
tonating an inflammable compound taped, to the balloon, rupturing iia side and
parmi tting a rapid escape of' the lifting gas.

Cases discussed

About this file

FOIA release, from the osd collection. The PDF is mirrored here; the original link is under it. 993 pages are in the text index: search them above, or from the library's search.