“Headquarters”29 pages
- p. 1 THE
ROSWELL
REPORT
Fact versus Fiction
in the
New Mexico Desert
Headquarters United States Air Force…
- p. 7 Clinical Investigations and Life Sciences Division, Headquarters Air Force Medical
Operating Agency, Bolling AFB, DC; John…
- p. 28 …the disc had been "flown to higher headquarters." That same
story also reported that a Roswell…
- p. 30 …These locations
include Fort Worth, Texas, the home of the Eighth Air Force Headquarters;
possibly Sandia…
- p. 71 DEPARTMENT OF THE AIR FORCE
HEADQUARTERS UNITED STATES AIR FORCE
MEMORANDUM FOR
FROM: AFiiN
SUBJECT:
References…
- p. 75 …DuBose says
officials at the Headquarters of the Eighth Air Force were
directed to tell the…
- p. 81 DEPARTMENT OF THE AIR FORCE
HEADQUARTERS UNITED STATES AIR FORCE
WASHINGTON DC
MEMORANDUM FOR SAF/AAZ…
- p. 89 DEPARTMENT OF THE AIR FORCE
HEADQUARTERS UNITED STATES AIR FORCE
09 Mar94
MEMORANDUMFORSAF/AAZ
ATIENTION: Lt…
- p. 107 …Colonel Loberg,
Headquarters, Eighth Air Force, arrived this date to
coordinate with S-3 and check…
- p. 108 …Boatright,
Headquarters, Eighth Air Force, arrived to coordinate with
Statistical Control on cost analysis.
16 July…
- p. 133 HEADQUARTERS, ARMY AIR FORCES
WASHINGTON
SUBJECT: Iuuance o! Ordera
!01 Couaa8.1ng General
.A.1r Materiel…
- p. 144 …we haven't s~uadron or grou~
headquarters should take their people away.
1:55 P…
- p. 159 …I did not make a report of this incident to my headquarters since I felt that…
- p. 165 …700 CIC was the CIC Headquarters.
- p. 166 …700 CIC was the Headquarters?
SC: Yes, I don't think I even made a report…
- p. 167 …I think this was taken at the Headquarters at Carswell.
RW: Yeah, that's right. That…
- p. 168 …I took it to 8th Air Force Headquarters, General Ramey was excited; they were
going to…
- p. 177 …I don't even want 700 CIC Headquarters to know we wasted our time on it…
- p. 178 …So that, to me, implies that this would have been
your CIC Headquarters also sent some…
- p. 227 …I was assigned, believe it or not, to Headquarters, Air
Force .•• I still have the Headquarters…
- p. 265 …on the basis of orders out of Headquarters
Army Air Force.
Q: While you were operating…
- p. 266 …These are the pictures taken in General Ramey's office,
8th Air Force Headquarters by a…
- p. 282 …Then after I left the headquarters of ARDC in
Baltimore, I spent four years at the…
- p. 318 …debris be flown to Eighth
Air Force Headquarters at Fort Worth AAF, TX, for his personal…
- p. 327 …Andrews AAF was headquarters
of the Army Air Forces Weather Service. It is also interesting to…
- p. 407 HEADQUARTERS FITZWILLIAM FORWARD
c/o Commander, Task Group 7.2
APO 187, c/o Postmaster
San…
- p. 409 …arrival of the explo-
sion sound wave. Headquarters FITZ\nlliArA FCRI1ARD furnished ARPACAS 3-1 and…
- p. 964 …Morgan, from Headquarters Eighth Air
Force, ;'las here to confer with the Engineering Officer,
Captain ?cterson…
- p. 984 …Marcellus Duffy eliminated
it and several others from the project when Headquarters U.S.
Army Air…
of displacement switch actions alone.
...0
:::>
...
IF LEVELING OFF TOO LOW, H.IGH
BALLAST RATE PUSHES BALLO.ON
INTO CONTROL ALTITUDE.
CASE "A"
, ~;;;-"' ~ -- -- -- -- -- -- -- ---- - -
... -~TOOL~' -- ,..-, ,--..
~ -~ASE "a"---.;;..;._~--
IF LEVELING OFF TOO HIGH
----- ---- _ _Lw:!BA:~A~T-U~T~ TH~~!~ME.
I ______l ____l ____ I ______ I_---=~~---_-
NORMAL 8ALLAST FLOW- CASE "A"
~~---------------~=-~~~~==-----:~:.:To~:l'i.L:~~SE aAI.!,AST FLOW- CASE "a" !RATE SWITCH FAILUREl-
TO INDICATIE PROPER
CONTROL ACTION. (!) PEN OFF SHELF
TIME
@ TOP LOW ALT. COMMUTATOR
@ aOTT. HIGH ALT. COlliN.
Figure 15. Theoretical height-time curve.
(4) Rate-of-Descent Switch
It may at times be desirable to control a balloon merely qya
switch activated at any given rate of descent. This could be
accomplished merely by "reversing" the rate-of-ascent switch.
This type of control would prove to be quite difficult, however,
for a constant level flight. One flight, No. 97, was made
using a type of rate-of-descent switch ·&s shown in Figure 16. In
...---------------------------------1
I
I Pos1tron whrle-,-~--------
rrsrng ..: ----------
1 AdJustable \_ Posrtron whrle
I Contact --...... ---, Descendrng
I I
I !I
L __ _ ' Ballast I'\_Solenard 1
1
Valve !
I I
L_~'l'l'l~~
Sealrng Valve
(Actuated at
de11red altrtude)
Figure 16. Rate-of-descent switch.
Coprllory
Tube