The Roswell Report: Fact versus Fiction in the New Mexico Desert was published in 1995 by Headquarters United States Air Force. It was written in response to Representative Steven H. Schiff's request and a General Accounting Office audit, and it contains Col. Richard L. Weaver's report and 1st Lt. James McAndrew's synopsis, along with attachments, appendices and photographs. The report says researchers found no evidence of an extraterrestrial craft or crew. It concludes that the 1947 debris came from a Project MOGUL balloon train.

  • p. 143 …Robert Gross ar.d 't!r. Jlaher of Lockheed 11~ 55 A.'.!. Gen. Sam Anderson 12…
  • p. 481 …Balloon Volume x Gas Lift Gross Load · It may be noted from this equation that a…
  • p. 482 …Balloon Volume x 24.4 Gross Load K =-w K _ 08.o475Z In turn, w-in…
  • p. 483 …free lift in pounds and G is gross lift in pounds. Although this equation was derived…
  • p. 488 …By equation {10), with a gross load of 52 kg., the unbalance caused by loss of…
  • p. 500 …or a gross buoyancy of 450 lb. • the maximum allowable infle.tion of a 30' diameter…
  • p. 569 …accelerating force equal to 5% of the gross load (52 kg) was acting to bring the…
  • p. 643 …000 feet. In one step, this becomes: Gross Lift/Balloon = (Balloon Volume) x (Difference in molecular…
  • p. 650 (Approximate) where G • gross load A chart, Figure 24, has beendrawn up, based on this equation…
  • p. 652 …G = loss of lift G =gross load (balloon weight plus equipment load) AT : mean temperature difference…
  • p. 653 …not including balloon or its integral parts. Gross load: Load on the gas at release (Balloon…
  • p. 726 …Ballast • • .. • • '" • Total Equipment l~eight. • • • • ' Gross Load • • ' • • • • {56)
  • p. 727 …Balloon volwne x gas litt/mol gross load cu. ft. -----------------NAximum Altitude • • • ft, m.s.l…
  • p. 741 …altitude deter- mined by the displacement and gross load. 7. Control systems Two systems of control…
  • p. 777 …By adjusting th~ gross load to be supported by the gas to equal the total lift…
  • p. 787 …Computations A chart showi~ the relation between altitude, gross lift, and balloon size has been found…
  • p. 883 …The gross load reported should be accurate to the nearest 200 grams. The amount of lifting…
  • p. 885 …A L L 0 0 N 7300 ,, GRoss LoAD Fl G. 17 NYU BALLOON pROJECT I…
  • p. 887 …bubble length and resultant inflated volume, using gross lift as an expression of volume. It will…
  • p. 889 …in Appendix II summarizes the relationship between gross load and floating level for balloons of several…
  • p. 925 …A can of sand is made to weigh the same amount as the required gross lift…
  • p. 933 …the balloon with the equipment load attached. Gross Lift: Lift of all of the gas in…
  • p. 938 …description.______________ Drag chute ---------------------------- Banner description --------------- ---------- Ballast assembly - description -----------~-- Ballast • • • • • • Total Equipment i'ieight • • ' • • • • • • Gross Load • • • • • • • • • • • -86-
  • p. 939 …wnitin_,g________ grams Actual balloon lift • • • • • • • • ". . .• II AActunl gross lift (Balloon lift & balloon wt.) • Number Helium…
  • p. 943 …Gross Lift vs. Bubble Length • • • • • • .107 Graph 3: Buoyancy vs. Altitude • • • • • • • • • .108 Graph 4: Gross Load…
  • p. 955 …BALLOOO DA 'fA General Mills Actual Balloon Estimated Gross Altitude ~ominal Diiameter Volwne Weight Load Limit…
The pen drops off the shelf at a safe distance below the ex-
pected pressure altitude and ballast then flows until the
preuure pen reaches the insulating section of the commutator.
In order to prevent the-overshoot mentioned as one undesirable
feature of the automatic ballast system, the high pressure
end of the insulator may correspond to the expected maximum
altitude of the balloon, any loss of lift due to impurities
or escape of lifting gas will cause the balloon to level off at
a ceiling within the ballast-dropping range. Continued ballast
dropping will result in the rise of the balloon. Thus, an over-
estimation of the ceiling is not as critical as in the case of
the previous system.
(3) Rate-of-Ascent Switch
Wit·h the displacement-switch control just described there re-
main the problems of ballast waste and balloon oscillation re-
sulting from discharge of ballast during rises of the balloon
after a descent has been checked. To eliminate this, a ballast-
control .witch acting on the rate of rise of the balloon is
put in series with the displacement ~itch to close the ballast
flow circuit only when the balloon is coming down or floating
below pressure altitude. When it is rising, no ballast flow is
permitted. This "rate-switch" is seen in Figure 12.
Wax
/Capillary
/ Tube
Volume
Chamber
Figure 12. Rate-of-ascent nitch.
-21-